Indications
In the presence of a gradient of less than 20-25%, apply a bituminous membrane on top of the multilayer wood.
The ventilation battens must have a minimum height of 5 cm and a distance between them of at least 50/60 cm.
Specification wording
Positioning the joggle edge.
Laying Isoventilato panels with the battens parallel to the gutter line.
Fixing the panels with self-tapping screws directly onto the incorporated batten or with polyurethane glue.
Sealing the joins between the panels with a waterproof self-adhesive strip of butyl aluminium.
Positioning and fixing the ventilation battens and the multilayer support, using nails or self-tapping screws directly onto the battens incorporated in the foam.
Laying Canadian type bituminous tiles.
Fixing system
-
on wood with self-tapping screws with length at least one and a half times the thickness of the panel
-
on clay/cement mix with expansion fixtures
- on concrete with expansion fixtures
Products
Isoventilato |

|